Service Pack 7 (Build 3.03.1264)
- Enhances area & weight calculations for V-Notches for non S&D connectors.
- Improves the connector hole positions when adding holes to parts.
Service Pack 6 (Build 3.03.1258)
- Improves the Profile feature so that valid and expected paths are created when using Copy All.
- Improves Design Line rotation when placing an inline item, such as a valve or vav, so that the node is set to “Default”.
- Improves stability when importing imperial services.
- Improves Takeoff as Cut In for directional hangers.
- Improves stability when editing sub assembly items that do not contain any graphics.
Service Pack 5 (Build 3.03.1238)
- Improved stability in using Multi Service Takeoff with Hangers when objects are pre-selected.
- Improved stability when using a Z Strap Hanger while using the Fix Relative option.
- Improved subassemblies when merging jobs.
- Improved the updating of support cost information when rod length changes.
- Improved multi-selecting values for ancillaries.
- Improved the display of swage connectors when the swage length value is less than 1 but greater than zero.
- CIDs 7, 417, 947 – Enhanced dimensional accuracy when using connector straight adjusts with the Top Extension.
- CID 104 – The 3D model length is now consistent with that of CID 8.
- CIDs 114, 355, 356, 357, 358, 359, 580, 831, 889 – Improved Insulation to be central from branch.
- CID 397 – Improved stability when developing holes.
- CID 518 – The visibility of the exhaust fan symbols has been improved.
- CID 996 – Improved reporting of C2 end size.
- CID 1112 – Improved sheet metal developments when the part is lined or lagged.
- CID 2873 – Improved reporting out size Annotation.
Service Pack 4 (Build 3.03.1164)
- CID 838 – Improved placement of Profile bearer when configured with -ve left or right angled bearer.
- Improved stability when using compact database with services that have specifications or Insulation specifications assigned.
Service Pack 3 (Build 3.03.1162)
- CID 838 – Improvement made to the elevation when taking off hangers when the Oversize Item is set to yes.
- CID 62 – Improved insulation so that it is central on the branch.
- CID 311 – Improved insulation so that it is central on the branch.
- CID 379 – Improved insulation so that it is central on the branches.
- CID 832 – Improved insulation so that it is central on the branches.
- CID 886 – Improved insulation so that it is central on the branch.
- CID 7 – Improved connector size for the C2 end.
- CID 1115 – Improved conical branch to be configured straight.
- Stability improvement made when importing .rif files.
- Enhanced window select for Raster underlays when selecting items.
- Improved stability when taking off Collections.
- Enhancement made to the Ancillaries dialog usability when using the tab key.
- Enhancement made to the Connectors dialog usability when using the menu key.
- Stability improvement made to Design Line when filling in multiple taps along a straight duct.
- Improvement made to the performance to the Editor Dialog of Design Line.
- Improved Terminal rotation when being placed.
- Improved reporting out Qty for Oval items in Design Line.
- Improved Hanger positioning on design lines when the ‘float’ option is used.
- Improvement made when re-filling Tee’s in Design Line.
Service Pack 2 (Build 3.03.1122)
- CID 101 – Improved Imperial dimensions.
- CID 17 – Improved Gasket allowance when Double Wall is enabled.
- CID 2524 – Stability improvement made when opening job.
- CID 2965 – Improved connector positions when using Offset Reducers & geometry when insulated.
- CID 4 – Improved connector straight allowance for extensions.
- CID 4 – Improved Gasket allowance when Double Wall is enabled.
- CID 965 – Improved connector positions when using Offset Reducers & geometry when insulated.
- Improved Fabrication items by allowing functions to be used in calculated dims.
- Improved usability when removing holes along with seams for straight duct patterns.
- CID 838 – Improved Type/Profile Option combinations.
- Improved Rectangular Straight Adjusts for Taps.
- Improved visibility for Step Down Connectors.
- Improved Export 2D Annotation.
- Enhanced Fabrication & Install rates associated with owned connectors to be editable.
- Improved support for raster PDF underlays.
- Stability improvement made to temporary database settings.
- Improved stability for Insulation Developments.
- Improved usability when removing Top Fixings Structure types.
- Enhanced Takeoff As Cut In for Hangers to size outside of the insulation.
- Improved stability when accessing the connector database when it contains no entries.
- Stability improvement made to Import Underlay Layers.
- Improved Dynamic Holes Developments.
- Improved complex nodes in design line.
- Improvement made to Design Line to include flanges when branch runs are present.
- Improved Design Line Pressure Drop Dialog to Export Data.
- Improved stability with Design Line constraints when adding restrictions.
- CID 2108 – Improved Design Line fill.
- Improved Design line fill for Rectangular Taps.
- Improvement made to Export Items Data when reporting out Square to Round Offset Depth.
- Improved scripting for owned content.
- Improved stability to Product Information Viewer.
- Stability improved for connector node tool tip annotation.
- Enhanced SetText Lisp method so that it does not add data to objects without Custom Text entries.
- Enhanced Site Difficulty Factor to view Print Objects.
- Stability improvement made when using Print Preview in Item Reports.
- Improved Insulation data output for reports.
- Improvements made in printing Stiffener Breakpoints.
Service Pack 1 (Build 3.03.1032)
- CID 535 – Improved Draw Type Options.
- CID 4 – Improved insulation.
- Stability improvement made when removing holes from straight ducts.
- Stability improvement made when loading jobs with dampers.
- Improved Dynamic Hole Developments.
- Improved Job Info to increment the number when creating a new job after Batch Process.
- Improvement made to migration of legacy install where all folders were not being copied over.
- Improvement made to Dynamic Holes when branches are mirrored.
- Stability improvement made to Path Repair Tool.
- Stability improvement made when downloading content.
- Improvement made to Design Line as reducing bends failed to fill when creating a riser.
- Improvement made to Design Line re-filling the wrong items.
- Improvement made to Design Line as reducer was failing to fill when option set to Input Angle.
- Improvement made to Design Line pressure drop calculations as they were failing at low flow rates.
- Improvement made to Editmap.exe for option to save EST tables, previously the setting was not being remembered.
- Improved stability when adding reports that have pressure drop & velocity fields for calculations.